Concrete Mix Design Calculator
Inputs
psi
ACI 318: residential 3,000–4,000 psi; structural 4,000–6,000 psi; parking/bridges 4,500+ psi
ACI 318 Table 19.3.3.1: severe exposure max 0.40 w/cm; moderate 0.45; general 0.50 max
lb/yd³
Tab to move between fields
Results
Cement
564 lb/yd³
Estimated Strength
7,502 psi
Water254 lb/yd³
Fine Aggregate (Sand)1,315 lb/yd³
Coarse Aggregate1,817 lb/yd³
Yield27.23 ft³