Calculate sensible heat, latent heat, total heat duty, and power requirements for process heating and cooling operations.

Inputs

kg/hr
kJ/(kg·°C)
°C
°C
kJ/kg
kg/hr

Results

Sensible Heat

114,950 kJ/hr

Total Heat Duty

114,950 kJ/hr

Latent Heat0 kJ/hr
Power Required31.93 kW
How to Use This Calculator
  1. Enter the Mass Flow Rate in kg/hr of the process stream.
  2. Enter the Specific Heat (Cp) in kJ/(kg·°C): water = 4.18, air ≈ 1.005, oils ≈ 1.8–2.1 kJ/(kg·°C).
  3. Enter the Inlet and Outlet Temperatures in °C to define the sensible heat duty.
  4. If a phase change occurs (condensation, vaporization), enter the Heat of Phase Change in kJ/kg and the Phase Change Mass in kg/hr — set to 0 if there is no phase change.
  5. Read the Total Heat Duty in kJ/hr and Power Required in kW to size heaters, coolers, or heat exchangers.
  6. Compare Sensible Heat and Latent Heat contributions to understand which dominates the design.