Blast-Resistant Glazing Calculator
Glass laminate layup from blast threat level.
Inputs
Results
Peak pressure (kPa)
60.1
Glass ply thickness (mm)
25
Scaled distance Z (m/kg^⅓)6.46
Positive phase (ms)10.6
Impulse (kPa·ms)317
Number of glass plies2
Interlayer thickness (mm)1.52
Total build-up (mm)51.5
Panel weight (kg)386.4
GSA hazard level (1-4)3
How to Use This Calculator
- Enter the threat level per GSA/DoD standards and standoff distance in feet.
- Set the window area and aspect ratio.
- Review the required glass makeup (monolithic, laminated, or blast film) and frame anchorage forces.
- Verify the hazard rating meets the target protection level (low, medium, or high).
- Use the anchorage forces in structural design to specify connection hardware.