Skip to main content
Calcimator

Structural Glazing Calculator

Silicone adhesion from glass weight and wind load.

Inputs

Results

Design bite (mm)

74

Joint thickness (mm)

37

Wind load bite (mm)5.4
Dead weight bite (mm)49.1
Sealant perimeter (m)7.8
Sealant volume (mL/panel)21,356
Cartridges per panel68.89
Glass panel weight (kg)90
How to Use This Calculator
  1. Enter the glass panel width and height.
  2. Set the design wind suction pressure and structural silicone bite dimension.
  3. Input structural silicone adhesive strength.
  4. Review the required silicone bite to resist the design load.
  5. Verify the calculated bite exceeds the minimum per ASTM C1184 and manufacturer requirements.