Water Penetration Test Calculator
Test pressure from building height and wind zone.
Inputs
Results
Design wind pressure (Pa)
1,830
Static test pressure (Pa)
439
C&C interior zone (Pa)2,196
C&C corner zone (Pa)3,293
Field spray pressure (Pa)439
Kz factor1.41
Spray flow rate (L/hr)510
Total water for test (L)128
Dynamic Test Pressure439.12
Spray Flow GPM2.25
Performance GradeLC (Light Commercial)
How to Use This Calculator
- Enter the curtain wall area under test and the test pressure in psf (ASTM E1105 or AAMA 501.1).
- Set the water application rate in gallons per hour per square foot.
- Input test duration in minutes.
- Review the total water volume applied and pass/fail criteria.
- Document test results by unit location for the project submittal record.