Test pressure from building height and wind zone.

Inputs

Results

Design wind pressure (Pa)

1,830

Static test pressure (Pa)

439

C&C interior zone (Pa)2,196
C&C corner zone (Pa)3,293
Field spray pressure (Pa)439
Kz factor1.41
Spray flow rate (L/hr)510
Total water for test (L)128
Dynamic Test Pressure439.12
Spray Flow GPM2.25
Performance GradeLC (Light Commercial)
How to Use This Calculator
  1. Enter the curtain wall area under test and the test pressure in psf (ASTM E1105 or AAMA 501.1).
  2. Set the water application rate in gallons per hour per square foot.
  3. Input test duration in minutes.
  4. Review the total water volume applied and pass/fail criteria.
  5. Document test results by unit location for the project submittal record.