Marine Pile Design Calculator

Compute ultimate and allowable bearing capacity for marine foundations on the seabed using the general bearing capacity equation with submerged soil conditions.

Inputs

Results

Ultimate bearing capacity (kPa)

910.9

Allowable bearing capacity (kPa)

364.4

Allowable total load (kN)

13,117.6

Foundation area (m²)36
Nc factor20.72
Nq factor10.66
Nγ factor10.88
How to Use This Calculator
  1. Enter seabed soil parameters: undrained shear strength (kPa), friction angle (degrees), and submerged unit weight (kN/m3).
  2. Enter foundation width (m) and length (m).
  3. Read ultimate bearing capacity (kPa) from the Meyerhof or Hansen formula.
  4. Apply appropriate safety factors (typically 2.5-3.0) to get allowable bearing capacity.
  5. Verify pile tip resistance and skin friction contributions separately for pile design.