Skip to main content
Calcimator

Recirculating System Design

Design a recirculating aquaculture system (RAS) with biofilter sizing, pump requirements, and tank volume based on fish biomass and feed rate.

About this calculator

Recommended Tank Volume depends on exactly one input — Fish Biomass — using a 0.5 lbs-fish-per-gallon rule of thumb common for intensive RAS stocking density. Feed Rate and Target Water Temperature have zero effect on it. Biofilter Media Area instead depends on Fish Biomass and Feed Rate together: it works backward from daily feed (biomass times feed rate as a percentage of body weight) through an assumed 3% total-ammonia-nitrogen (TAN) production rate and a fixed nitrification rate per square foot of moving-bed media, so both a bigger fish load and a higher feed percentage push it up, and Target Water Temperature never enters that calculation at all — this calculator does not model how nitrification efficiency actually varies with temperature, which real biofilters do.

Pump Flow Rate and Total System Volume follow from tank size plus biofilter size plus an assumed 20% sump allowance, turned over at a fixed 1.5 times per hour — again with no temperature dependence. Heating/Cooling Load is the one output that does use Target Water Temperature, comparing it against an assumed 20°C (68°F) room temperature and scaling the load by the size of the difference in either direction — set the target near 68°F and the estimated load shrinks toward zero; move it further away in either direction (colder or warmer) and the load grows. None of these are substitutes for site-specific engineering: real biofilter sizing accounts for pH, alkalinity, and species-specific ammonia tolerance that this simplified model omits.

Inputs

lbs
%
°F

Results

Biofilter Media Area

2,922 ft²

≈ 12 one-car garages

Recommended Tank Volume

1,000 gallons

≈ 25 bathtubs

Pump Flow Rate

39 GPM

Biofilter Volume358 gallons
Total System Volume1,558 gallons
Solids Filter Capacity78 GPM
Daily Feed15 lbs
Daily Ammonia Production0.45 lbs TAN
Daily Oxygen Demand7.5 lbs O₂
Heating/Cooling Load5,195 BTU/hr
How to Use This Calculator
  1. Enter Fish Biomass, Feed Rate, and Target Water Temperature.
  2. Review Biofilter Media Area (ft²), Recommended Tank Volume (gallons), and Pump Flow Rate (GPM).
  3. Use Biofilter Volume (gallons) and Total System Volume (gallons) to inform your decision.
  4. Use the chart to visualize the results and explore different scenarios by adjusting inputs.

How the result changes with Fish Biomass

Fish BiomassBiofilter Media AreaRecommended Tank VolumePump Flow Rate
2501,461 ft²500 gallons19 GPM
3752,192 ft²750 gallons29 GPM
7504,383 ft²1,500 gallons58 GPM
1,2507,305 ft²2,500 gallons97 GPM

What each input means

Fish Biomass
Total weight of fish in the system in pounds.
Feed Rate
Daily feed as percentage of fish body weight. Typical: 2-4% for grow-out.
Target Water Temperature
Desired water temperature for your species. Affects heating/cooling needs.

How this is calculated

Worked example, using the default values

  1. Identify Input Parameters
    Fish Biomass = 500, Feed Rate = 3, Target Water Temperature = 80 = 3 input(s) provided
  2. Calculate Biofilter Media Area
    2922 = 2922
  3. Calculate Recommended Tank Volume
    Recommended Tank Volume
    1000 = 1000
  4. Calculate Pump Flow Rate
    Pump Flow Rate
    39 = 39
  5. Calculate Biofilter Volume
    Biofilter Volume
    358 = 358
  6. Calculate Total System Volume
    Total System Volume
    1558 = 1558

Engine last updated . Checked against 1 independently-derived test — how we verify calculators. Built by Paul Gunder, a software engineer, not a licensed financial, medical, or legal professional.

Frequently Asked Questions

Why doesn't Target Water Temperature change my Recommended Tank Volume?

Recommended Tank Volume is calculated purely from Fish Biomass using a stocking- density rule of thumb (0.5 lbs of fish per gallon, typical for intensive RAS). Feed Rate and Target Water Temperature drive other outputs — biofilter sizing and heating load respectively — but neither has a mathematical connection to tank volume in this model.

What increases Biofilter Media Area — bigger fish load or higher feed rate?

Both do, and roughly proportionally. Biofilter Media Area is sized from daily total-ammonia-nitrogen production, which is Fish Biomass multiplied by Feed Rate (as a percentage of body weight) multiplied by a fixed 3% TAN conversion factor — so raising either biomass or feed percentage by the same proportion raises the required biofilter area by roughly that same proportion.

Does raising Target Water Temperature always increase the Heating/Cooling Load?

No — the load is based on how far Target Water Temperature is from an assumed 68°F (20°C) room temperature, in either direction. Moving the target closer to 68°F shrinks the estimated load toward zero; moving it further away — whether colder or warmer — increases it, since the calculator estimates both heating and cooling demand the same way.

Does this account for how nitrification efficiency changes with temperature?

No — Biofilter Media Area uses a single fixed nitrification rate regardless of Target Water Temperature, even though real biofilm nitrification is temperature-sensitive and typically slows notably in colder water. This calculator is a sizing starting point, not a substitute for species- and site-specific biofilter engineering.

The questions that sit next to this one — chosen by subject, including calculators filed under a different category.

More in Agriculture & Farming.