Recirculating System Design
Design a recirculating aquaculture system (RAS) with biofilter sizing, pump requirements, and tank volume based on fish biomass and feed rate.
About this calculator
Recommended Tank Volume depends on exactly one input — Fish Biomass — using a 0.5 lbs-fish-per-gallon rule of thumb common for intensive RAS stocking density. Feed Rate and Target Water Temperature have zero effect on it. Biofilter Media Area instead depends on Fish Biomass and Feed Rate together: it works backward from daily feed (biomass times feed rate as a percentage of body weight) through an assumed 3% total-ammonia-nitrogen (TAN) production rate and a fixed nitrification rate per square foot of moving-bed media, so both a bigger fish load and a higher feed percentage push it up, and Target Water Temperature never enters that calculation at all — this calculator does not model how nitrification efficiency actually varies with temperature, which real biofilters do.
Pump Flow Rate and Total System Volume follow from tank size plus biofilter size plus an assumed 20% sump allowance, turned over at a fixed 1.5 times per hour — again with no temperature dependence. Heating/Cooling Load is the one output that does use Target Water Temperature, comparing it against an assumed 20°C (68°F) room temperature and scaling the load by the size of the difference in either direction — set the target near 68°F and the estimated load shrinks toward zero; move it further away in either direction (colder or warmer) and the load grows. None of these are substitutes for site-specific engineering: real biofilter sizing accounts for pH, alkalinity, and species-specific ammonia tolerance that this simplified model omits.
Inputs
Results
Biofilter Media Area
2,922 ft²
≈ 12 one-car garages
Recommended Tank Volume
1,000 gallons
≈ 25 bathtubs
Pump Flow Rate
39 GPM
How to Use This Calculator
- Enter Fish Biomass, Feed Rate, and Target Water Temperature.
- Review Biofilter Media Area (ft²), Recommended Tank Volume (gallons), and Pump Flow Rate (GPM).
- Use Biofilter Volume (gallons) and Total System Volume (gallons) to inform your decision.
- Use the chart to visualize the results and explore different scenarios by adjusting inputs.
How the result changes with Fish Biomass
| Fish Biomass | Biofilter Media Area | Recommended Tank Volume | Pump Flow Rate |
|---|---|---|---|
| 250 | 1,461 ft² | 500 gallons | 19 GPM |
| 375 | 2,192 ft² | 750 gallons | 29 GPM |
| 750 | 4,383 ft² | 1,500 gallons | 58 GPM |
| 1,250 | 7,305 ft² | 2,500 gallons | 97 GPM |
What each input means
- Fish Biomass
- Total weight of fish in the system in pounds.
- Feed Rate
- Daily feed as percentage of fish body weight. Typical: 2-4% for grow-out.
- Target Water Temperature
- Desired water temperature for your species. Affects heating/cooling needs.
How this is calculated
Worked example, using the default values
- Identify Input ParametersFish Biomass = 500, Feed Rate = 3, Target Water Temperature = 80 = 3 input(s) provided
- Calculate Biofilter Media Area2922 = 2922
- Calculate Recommended Tank VolumeRecommended Tank Volume1000 = 1000
- Calculate Pump Flow RatePump Flow Rate39 = 39
- Calculate Biofilter VolumeBiofilter Volume358 = 358
- Calculate Total System VolumeTotal System Volume1558 = 1558
Engine last updated . Checked against 1 independently-derived test — how we verify calculators. Built by Paul Gunder, a software engineer, not a licensed financial, medical, or legal professional.
Frequently Asked Questions
Why doesn't Target Water Temperature change my Recommended Tank Volume?
Recommended Tank Volume is calculated purely from Fish Biomass using a stocking- density rule of thumb (0.5 lbs of fish per gallon, typical for intensive RAS). Feed Rate and Target Water Temperature drive other outputs — biofilter sizing and heating load respectively — but neither has a mathematical connection to tank volume in this model.
What increases Biofilter Media Area — bigger fish load or higher feed rate?
Both do, and roughly proportionally. Biofilter Media Area is sized from daily total-ammonia-nitrogen production, which is Fish Biomass multiplied by Feed Rate (as a percentage of body weight) multiplied by a fixed 3% TAN conversion factor — so raising either biomass or feed percentage by the same proportion raises the required biofilter area by roughly that same proportion.
Does raising Target Water Temperature always increase the Heating/Cooling Load?
No — the load is based on how far Target Water Temperature is from an assumed 68°F (20°C) room temperature, in either direction. Moving the target closer to 68°F shrinks the estimated load toward zero; moving it further away — whether colder or warmer — increases it, since the calculator estimates both heating and cooling demand the same way.
Does this account for how nitrification efficiency changes with temperature?
No — Biofilter Media Area uses a single fixed nitrification rate regardless of Target Water Temperature, even though real biofilm nitrification is temperature-sensitive and typically slows notably in colder water. This calculator is a sizing starting point, not a substitute for species- and site-specific biofilter engineering.
Related Calculators
The questions that sit next to this one — chosen by subject, including calculators filed under a different category.
Water Quality Calculator
Assess aquaculture water quality by evaluating ammonia, nitrite, pH, dissolved oxygen, and temperature against safe thresholds for fish.
AquaculturePond Aeration Calculator
Determine the horsepower needed for pond aeration based on pond size, stocking density, and water temperature.
AquacultureAquaculture Feed Rate
Calculate daily feed requirements for fish based on total biomass, water temperature, and target feed rate percentage.
More in Agriculture & Farming.