Performance Lighting Calculator

Fixture count and power from stage area and effects.

About this calculator

This calculator sizes a theatrical lighting rig by working backward from an inverse-square light model: a reference 575W ellipsoidal fixture is assumed to deliver 1,700 lux over a 7 m² pool at a 5m throw, and both lux and coverage area are scaled by the ratio of your throw distance to that 5m reference (lux falls off with the square of distance, while the covered area grows with its square). Dividing your stage area by the per-fixture coverage gives a baseline fixture count, which is then scaled up if your target lux exceeds what a single tiled layer produces. On top of that front wash, the tool adds rule-of-thumb allowances for supporting systems: one backlight fixture per 4 m² of stage, side/cross light fixtures scaled to stage depth, and a minimum of four "specials" for solos and set pieces.

Total power draw follows directly from fixture count times wattage-per-type (575W conventional, ~150W LED, ~350W moving head), reported in kW and as amperage at both 120V and the 208V three-phase service typical of theatrical venues. DMX channel counts assume 1 channel per conventional dimmer, 6 per LED fixture (RGBW+ dimming), and 16 per moving head, then divide by 512 to estimate DMX universes needed. Treat every number here as a rough-order-of-magnitude starting point for budgeting and rig planning, not a substitute for a lighting designer's plot — real designs vary enormously with fixture beam angle, gel/color choices, venue ceiling height, and house lighting positions that this simplified model doesn't capture.

Inputs

ft
ft
ft

Results

Front wash fixtures

10

Total fixtures

56

Stage area (m²)96
Back light fixtures24
Side light fixtures12
Specials10
Total power (kW)32.2
Total amps (208V)154.81
DMX channels56
DMX universes1
Fixture NameConventional
Total Amps20268.33
Dimmer Circuits56
How to Use This Calculator
  1. Enter stage width (m) and stage depth (m) for your performance space.
  2. Set the target light level (lux) — 500–800 for drama, 1000–1500 for dance/musical.
  3. Select fixture type (1 = Conventional 575W, 2 = LED ~150W, 3 = Moving Head ~350W).
  4. Review Number of Fixtures needed, Total Power (kW), and Circuit Load.
  5. Use the fixture count to plan your lighting rig, dimmer racks, and cable runs.

How the result changes with Throw distance (m)

Throw distance (m)Front wash fixturesTotal fixtures
33985
4.51763
9854
15955

What each input means

Stage width (m)
Width of the performance stage in metres.
Stage depth (m)
Depth of the stage from front to back.
Target light level (lux)
Desired illumination at stage level (500-800 drama, 1000-1500 musical/dance).
Fixture type (1-3)
1 = Conventional (575W), 2 = LED (~150W), 3 = Moving Head (~350W).
Throw distance (m)
Distance from lighting position to the stage (front of house to stage centre).

What each result means

Stage area (m²)
Total stage area.
Front wash fixtures
Number of fixtures for the primary front wash.
Back light fixtures
Fixtures for back lighting (separation and depth).
Side light fixtures
Fixtures for side/cross lighting from both wings.
Specials
Focused specials for solos, set pieces, and effects.
Total fixtures
Total fixtures for a complete lighting rig.
Total power (kW)
Total electrical power draw at full intensity.
Total amps (208V)
Current draw at 208V theatrical power.
DMX channels
Total DMX channels needed for all fixtures.
DMX universes
Number of DMX universes (512 channels each).

How this is calculated

Worked example, using the default values

  1. Identify Input Parameters
    4 parameters
    Stage width (m) = 12, Stage depth (m) = 8, Target light level (lux) = 800, Fixture type (1-3) = 1 = 5 input(s) provided
  2. Calculate Front wash fixtures
    Front wash fixtures
    10 = 10
  3. Calculate Total fixtures
    Total fixtures
    56 = 56
  4. Calculate Stage area
    Stage area = stageWidthM * stageDepthM
    96 = 96
  5. Calculate Back light fixtures
    Back light fixtures
    24 = 24

Engine last updated . Checked against 3 independently-derived tests — how we verify calculators. Built by Paul Gunder, a software engineer, not a licensed financial, medical, or legal professional.

Frequently Asked Questions

Why does moving the fixtures further back (increasing throw distance) change both the lux and the fixture count?

The calculator models light spreading with the inverse-square law: lux per fixture falls off with the square of throw distance, while the coverage area per fixture grows with that same square. A longer throw means each fixture lights a wider but dimmer pool, so it takes more fixtures tiled together to reach the same target lux over your stage area than a shorter, more concentrated throw would.

If I raise the target light level, does the front wash fixture count scale proportionally?

Close to it. The calculator first computes how many fixtures are needed just to physically tile the stage area, then multiplies that by the ratio of your target lux to the lux a single tiled layer produces at your throw distance. Doubling the target lux roughly doubles the front wash count once you're past the baseline coverage requirement, since the model assumes you're stacking fixture output rather than swapping to brighter units.

Why do LED and moving head fixtures need so many more DMX channels than conventional fixtures?

A conventional fixture on a dimmer only needs one channel to control its intensity, so the calculator assigns it 1 DMX channel. An LED fixture needs separate channels for red, green, blue, white, and dimming, so it's assigned 6. A moving head adds pan, tilt, color wheel, gobo, and other motorized parameters on top of that, so it's assigned 16 — which is why switching fixture types can push your total channel count past 512 and require an additional DMX universe.

What exactly are the 'specials' fixtures, and why is there always at least four?

Specials are fixtures the calculator sets aside for solos, set pieces, and focused effects that a general wash doesn't cover — it allocates roughly one per 10 m² of stage area, but never fewer than four regardless of how small the stage is, since even a modest production typically needs a handful of dedicated specials beyond the front wash, backlight, and side light systems.

The questions that sit next to this one — chosen by subject, including calculators filed under a different category.